A2/304 grade stainless steel fasteners for fixing timber battens to composite panel / liner tray
Estimated lead times
1 Day
Estimated lead times
1 Day
Stainless steel fasteners for fixing timber battens to composite panel and other thin sheet metal.
- Genuine A2 stainless steel for durability
- Purpose designed for easy and effective installation
- Buttress thread ensures good pull-out values
- For mechanically fixing timber battens and timber-like materials to thin steel
Years / Environment
|
|||||||
---|---|---|---|---|---|---|---|
Interior | Semi-interior | Rural | Urban | Industrial / Coastal | Marine | Swimming pools & Chemical plants | |
Corrosivity Category | C1 | - | C2 | C3 | C4 | C5 | - |
Austenitic Stainless Steel A2 Grade (304) | 30 | 25 | 25 | 25 | 15 | 0 | 0 |
NR,II,K (Tensile - Pull-out) | 1.2mm Steel: 2.81 kN |
2mm Steel: 4.78 kN |
Installation tool | Variable speed electric screw gun |
Installation drive | TX30 |
Installation speed | 1500 RPM |
Correct installation | Fasteners should be driven within three degrees of perpendicular to the surface of the fastened material. Use a depth-setting nosepiece to avoid over-driving, and do not over-tighten. Variants with bonded washers should not have the rubber compressed to less than two-thirds of its uncompressed height. Care should be taken when engaging and disengaging from the fastener head to avoid damage to the protective coating. |
Handling | Fasteners may have sharp edges, and the use of power tools can be dangerous. Use personal protective equipment. Store fasteners in dry conditions. Inspect each fastener before use and do not use damaged fasteners. |
Stainless steel fasteners for fixing timber battens to composite panel and other thin sheet metal.
- Genuine A2 stainless steel for durability
- Purpose designed for easy and effective installation
- Buttress thread ensures good pull-out values
- For mechanically fixing timber battens and timber-like materials to thin steel
Years / Environment
|
|||||||
---|---|---|---|---|---|---|---|
Interior | Semi-interior | Rural | Urban | Industrial / Coastal | Marine | Swimming pools & Chemical plants | |
Corrosivity Category | C1 | - | C2 | C3 | C4 | C5 | - |
Austenitic Stainless Steel A2 Grade (304) | 30 | 25 | 25 | 25 | 15 | 0 | 0 |
NR,II,K (Tensile - Pull-out) | 1.2mm Steel: 2.81 kN |
2mm Steel: 4.78 kN |
Installation tool | Variable speed electric screw gun |
Installation drive | TX30 |
Installation speed | 1500 RPM |
Correct installation | Fasteners should be driven within three degrees of perpendicular to the surface of the fastened material. Use a depth-setting nosepiece to avoid over-driving, and do not over-tighten. Variants with bonded washers should not have the rubber compressed to less than two-thirds of its uncompressed height. Care should be taken when engaging and disengaging from the fastener head to avoid damage to the protective coating. |
Handling | Fasteners may have sharp edges, and the use of power tools can be dangerous. Use personal protective equipment. Store fasteners in dry conditions. Inspect each fastener before use and do not use damaged fasteners. |