A4 (316 Grade) Stainless steel concrete fasteners for flat roofing.
Estimated lead times
1 Day
Estimated lead times
1 Day
Estimated lead times
1 Day
calcPageSize())"
/>
Estimated lead times
1 Day
Estimated lead times
1 Day
Estimated lead times
1 Day
For mechanically fixing single-ply and flat roofing systems to concrete and timber decks in combination with appropriate SureFast® components.
For mechanically fixing flat roofing accessories and trims to concrete
- High resistance to corrosion - suitable for use in marine environments
- Thread design developed to provide strong pull-out performance in accordance with EAD 030351‑00‑0402
- TX 25 Drive for controlled installation
- Compatible with the SureFast® range of tube washers and pressure plates
- ETA Approval and CE Marked.
- For mechanically fixing single-ply and flat roofing systems to concrete and timber decks in combination with appropriate SureFast components
| NR,II,K (Tensile - Pull-out) | 0.7mm Steel: 1.38 kN |
| Concrete C32/40 25mm Embedment: 3.66 kN |
| NR,II,K (Tensile - Pull-out) | 0.7mm Steel: 1.38 kN |
| Concrete C32/40 25mm Embedment: 3.66 kN |
| NR,II,K (Tensile - Pull-out) | 0.7mm Steel: 1.38 kN |
| Concrete C32/40 25mm Embedment: 3.66 kN |
| NR,II,K (Tensile - Pull-out) | 0.7mm Steel: 1.38 kN |
| Concrete C32/40 25mm Embedment: 3.66 kN |
| Installation tool | Variable speed electric screw gun |
| Installation drive | TX25 |
| Installation speed | 1500 RPM |
| Correct installation | Fasteners should be driven within three degrees of perpendicular to the surface of the fastened material. Use a depth-setting nosepiece to avoid over-driving, and do not over-tighten. Variants with bonded washers should not have the rubber compressed to less than two-thirds of its uncompressed height. Care should be taken when engaging and disengaging from the fastener head to avoid damage to the protective coating. |
| Handling | Fasteners may have sharp edges, and the use of power tools can be dangerous. Use personal protective equipment. Store fasteners in dry conditions. Inspect each fastener before use and do not use damaged fasteners. |
For mechanically fixing single-ply and flat roofing systems to concrete and timber decks in combination with appropriate SureFast® components.
For mechanically fixing flat roofing accessories and trims to concrete
- High resistance to corrosion - suitable for use in marine environments
- Thread design developed to provide strong pull-out performance in accordance with EAD 030351‑00‑0402
- TX 25 Drive for controlled installation
- Compatible with the SureFast® range of tube washers and pressure plates
- ETA Approval and CE Marked.
- For mechanically fixing single-ply and flat roofing systems to concrete and timber decks in combination with appropriate SureFast components
| NR,II,K (Tensile - Pull-out) | 0.7mm Steel: 1.38 kN |
| Concrete C32/40 25mm Embedment: 3.66 kN |
| NR,II,K (Tensile - Pull-out) | 0.7mm Steel: 1.38 kN |
| Concrete C32/40 25mm Embedment: 3.66 kN |
| NR,II,K (Tensile - Pull-out) | 0.7mm Steel: 1.38 kN |
| Concrete C32/40 25mm Embedment: 3.66 kN |
| NR,II,K (Tensile - Pull-out) | 0.7mm Steel: 1.38 kN |
| Concrete C32/40 25mm Embedment: 3.66 kN |
| Installation tool | Variable speed electric screw gun |
| Installation drive | TX25 |
| Installation speed | 1500 RPM |
| Correct installation | Fasteners should be driven within three degrees of perpendicular to the surface of the fastened material. Use a depth-setting nosepiece to avoid over-driving, and do not over-tighten. Variants with bonded washers should not have the rubber compressed to less than two-thirds of its uncompressed height. Care should be taken when engaging and disengaging from the fastener head to avoid damage to the protective coating. |
| Handling | Fasteners may have sharp edges, and the use of power tools can be dangerous. Use personal protective equipment. Store fasteners in dry conditions. Inspect each fastener before use and do not use damaged fasteners. |